high voltage power supply 50KV/1mA,
24V input, DC output
a. individual and integrated control unit, each PC board can test and check individually.
b. PWM voltage control mode
c. input rectification, high frequency inversion, high voltage rectification to supply voltage to the ESP equipment
d. constant voltage and constant current, working constantly in rated value, voltage and current can program individually.
e. fast modulation of output, reliable protection
f. can be worked in the conditions of short circuit and sparks.
e. over current, over voltage, less voltage protection
f. high accuracy of 4 ½ digits shown constantly
g. the resolution is 0.01KV to 0.01mA
24V input, DC output
a. individual and integrated control unit, each PC board can test and check individually.
b. PWM voltage control mode
c. input rectification, high frequency inversion, high voltage rectification to supply voltage to the ESP equipment
d. constant voltage and constant current, working constantly in rated value, voltage and current can program individually.
e. fast modulation of output, reliable protection
f. can be worked in the conditions of short circuit and sparks.
e. over current, over voltage, less voltage protection
f. high accuracy of 4 ½ digits shown constantly
g. the resolution is 0.01KV to 0.01mA
Item | Parameters | Remarks |
Input voltage | 24V DC | Wave less than 10% |
Rated power | 50W | Full load, output Umax, Imax |
Rated output voltage | 50kV | |
Rated output current | 1mA | |
Relative voltage control accuracy | 0.5% | Uo=80%*Umax |
Absolute voltage control accuracy | 1.5% | Uo=80%*Umax |
Voltage/temperature coefficient | 20V/1K | |
Voltage program accuracy | Better than 5% | |
Voltage output range | 0-50KV adjustable | |
Output limiting current | 1.0mA | |
Control response time | Better than 50mS | |
Ambient temperature | -20 ~ 50 C | |
Ambient humidity | 10%-90% no atomization | |
Cooling | Air cooling | |
Starting | Soft start | |
Constant voltage control mode | PWM | |
Current control mode | Constant current of average value Peak value testing | Within 100nS peak value testing, cut off and restart automatically |
Working frequency | 40kHz | |
Exchanging frequency | Better than 70% | Output voltage from 50%_75% , efficiency 80%_90% |
Voltage regulation rate | 0.5% | |
Current and voltage program mode | By potentiometer OR 0~5V voltage | |
Monitor | 0~5V voltage corresponding to 0 to full scale | |
Dimension | 220*220*100 mm L*B*H |